Manual Cement Compression & Flexure Testing Machines

Product Code

UTCM-6310

250 kN Manual Cement

Compression Testing Machine

UTCM-6410

15/250 kN Manual Cement Flexure

Compression Testing Machine

UTCM-0116

Upper Loading Platen with

Ball Seating Assembly Ø:165 mm

and Lower Loading Platen, Ø:165 mm

UTCM-0120/A

Flexure Jig Assembly to test

40x40x160 mm mortar prisms, ASTM

UTCM-0120/E

Flexure Jig Assembly to test

40x40x160 mm mortar prisms, EN

UTCM-0121/A

Compression Jig Assembly to test

50 mm (2”) mortar cubes

UTCM-0121/E

Compression Jig Assembly to test portions

of 40x40x160 mm mortar prisms, EN

UTCM-0122

Compression Jig Assembly BS,

to test 70,7 mm mortar cubes

Standards

EN 196-1, 459-2, 1015-11, 13454-2; ASTM C109, C348, C349; BS 3892-1, 4551-1

The UTCM-6310 and UTCM-6410 single and double testing chamber Manual compression and flexure testing machines are designed to perform reliable strength and flexure tests on mortar specimens. The manual machines are especially suitable for on-site applications when electric power supply is not available.

Being a low cost alternative, UTEST manual testing series combine precision and simplicity with the unique design of the manual power pack which enables even an inexperienced operator to perform excellent compression and flexure tests on-site.

These manual testing machines conform to the standards EN 196-1, 459-2, 1015-11, 13454-2; ASTM C 109, C348, C349 and BS 3892-1, 4551-1 by using suitable accessories. They also meet with the requirements of CE norms with respect to operator health and safety.

The UTEST manuel cement compression and flexure testing machines consist of very rigid two column single or double chamber frame, manuel power pack and data acquisition system LPI.

Compression and flexture jigs, distance pieces, and also removable transparent front-rear safety doors (should be factory installed) should be ordered separately.

Manuel Power Pack

The UTC-4810 Hand Operated (Manual) Power Pack has been designed to be used with range of UTEST Compression machines and flexural frames to use on site and/or where electricity is not available.

The pump is equipped with a radial piston pump so that the loading is continuous as long as user turns the wheel installed on the pump. The loading is uniform as on an automatic machine. The operator can easily load the machine up to 300 bars.

Dimensions

300x400x600 mm

Weight (approx.)

50 kg

LPI

The LPI Battery Operated Digital Readout Unit has been designed to use with load cells or pressure transducers on different material test applications.

The unit is operates with DC voltage source of -1,5 to 1,5 volts.

  • Real time numeric display of load and load rate
  • 1 channel with two different calibration table (can be used for 2 sensors)
  • Peak hold property
  • Multi-point calibration
  • Can operate with 2 x AA batteries
  • Easy preload zeroing
  • Serial port for PC or printer
  • 8 keys keyboard
Technical Specifications

Model

UTCM-6310

UTCM-6410

Test Type

Compression

Flexure

Compression

Capacity

250 kN

15 kN

250 kN

Class 1 Measuring Range

2.5 to 250 kN

0.5 to 15 kN

2.5 to 250 kN

The roughness value for texture of loading and auxiliary platens

 

≤3.2 μm

 

≤3.2 μm

 

≤3.2 μm

Lower Platen Dimensions

165 mm

165 mm

165 mm

Upper Platen Dimensions

165 mm

165 mm

165 mm

Maximum Vertical Clearance Between Platens

 

263 mm

 

263 mm

 

263 mm

Piston Diameter

160 mm

80 mm

160 mm

Maximum Piston Movement

50 mm

50 mm

50 mm

Horizontal Clearance

300 mm

200 mm

300 mm

Oil Capacity

13 L

13 L

Maximum Working Pressure

125 bar

30 bar

125 bar

Rapid Approach Rate

50 mm/min

80 mm/min

50 mm/min

Dimensions (WxLxH)

760x500x1650 mm

980x500x1650 mm

Weight

230 kg

375 kg

The Maximum horizontal clearance for placing the sample is limited by the border of the platens. Sample must be placed such that its ends will not overlap the ends of platens and it must be centered perfectly.The minimum vertical clearance for the specimen can be adjusted using the distance pieces.